E-MAIL NEWSLETTER

Sign up and NOW to receive the latest news, updates and technological advancements made for the Special Core Analysis & Enhanced Oil Recovery Industry

If you don't sign up, you won't know when the next breakthrough occurs!

News

Home/News
News 2016-10-25T11:54:46+00:00
2501, 2016

Ensuring Capillary Contact in Porous Plate Drainage Measurements using Impedance | Ask PERM

January 25th, 2016|Categories: Ask PERM (Q&A)|0 Comments

Joseph Asks PERM: Dear Sir/Madam, In Drainage Capillary pressure measurements using porous plate, how will you ensure that there is enough/good capillary contact between the core plug sample and porous plate? In most cases labs uses [...]

1801, 2016

Should Slim Tube Tests Use Reservoir Rock? | Ask PERM

January 18th, 2016|Categories: Ask PERM (Q&A)|0 Comments

Ehab Asks PERM: My question is related to the Slim Tube Test procedure and here it is; The porous media which fills the coiled tube through it the oil and solvent passes. Should this porous media [...]

1401, 2016

What is the Effect on Trapping of Oil Drop in a Pore Doublet Throat When Oil Viscosity is High? | Ask PERM

January 14th, 2016|Categories: Ask PERM (Q&A)|0 Comments

Aya asks PERM:  What will happen if viscosity of oil was not equal to viscosity  of water , what is the general effect on trapping of oil drop in a pore doublet throat if the [...]

1301, 2016

2016 Training Course Schedule for Engineers, Geologist and Petrophysicists, etc

January 13th, 2016|Categories: Courses|0 Comments

(Calgary, AB) - January 13, 2016 - PERM Inc.'s 2016 schedule for training classes is listed below.  These are 2-day courses hosted in Calgary, Alberta, Canada that are well suited for Geologists, Engineers and Petrophysicists [...]

401, 2016

General Rules of Thumb for Picking Injection Rates in a Core Flood? | Ask PERM

January 4th, 2016|Categories: Ask PERM (Q&A)|0 Comments

Binu Asks PERM: Dear sir, I am planning to conduct a core flood experiment using a restored core of 7 cm length, 3 cm diameter, 14% porosity and liquid permeability of 50 mD. The PV of [...]